The Single Best Strategy To Use For Dp50rb
The Single Best Strategy To Use For Dp50rb
Blog Article
Assist 4D probe; identify the probe through the ID code; switch the 4D generate signal by way of the electrical relay to produce the 4D probe get the job done Generally. four.two.two Major board The leading board can be divided into two components: front-conclusion of the leading board and back again-finish of the main board.
Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
The consumer is not really allowed to open the handles and panel of the technique, neither Observe: gadget disassemble is authorized. To make sure the method general performance and safety, only Mindray engineers or engineers authorized by Mindray can complete servicing.
Learn far better diagnostic information as a result of extended check out of the anatomical construction on all convex probes.
Return into the technique preset interface. The option standing adjustments into Uninstalled. The uninstalling purpose is exceptional to inside consumers.
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
S. ought to provide the Section with the electronic mail deal with if they may have just one. The emails supplied may very well be utilized for official conversation Using the licensee. Having said that email addresses are community report. If you don't would like to supply a personal address, remember to present the Office with an e-mail deal with which may be designed accessible to the public. To find out For anyone who is a licensee less than Chapter 455, File.S., you should Click the link . Solution Approval Accepts:
This guide might referring to facts guarded by copyright or patents and won't Express any license underneath the patent legal rights or copyright of Mindray, or of Other folks. Page nine: Assertion
The chapter provides the tactic to validate major function and effectiveness of product. This can be only utilized for reference, not preventive execution. Purpose checking and testing of this part shall be performed by Mindray support engineers along with the consumer collectively. Site 66: Basic Exam
Cookies are important to the proper operating of the site. To help your expertise, we use cookies to recollect log-in aspects and supply protected log-in, accumulate stats to enhance website performance, and provide material tailored to your pursuits.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
S. ought to supply the Office by having an email tackle if they've a person. The email messages provided could be useful for official communication Along with the licensee. Nonetheless e mail addresses are general public record. If you do not would like to produce a private address, make sure you give the Office with an email address which can be created available to the public. Make sure you see our Chapter 455 website page to find out For anyone who is influenced by this change.
Effectiveness Examination five.five.one Check System Resolution Detection depth Geometric Placement Accuracy Blackout area check Report the Test photographs five.five.two Exam Material The impression used Here's just for reference, stick with the picture influence in the true Observe: situation. Needs: Exhibit: set the contrast and brightness on the clinical application value (or maybe the default position) Operation natural environment: darkish place, simulating the medical application environment. Web page seventy six In ailment the transverse resolution screening targets are horizontally displayed, history the negligible distance of two targets that could be Obviously recognized. Repeat the Procedure previously mentioned to the transverse resolution testing targets at other depths. As demonstrated in figure below. Axial resolution ... Web site 77 When utilizing the convex probe, preserve the transverse resolution tests targets to NOTE: be shown close to the midline. When utilizing a linear probe Dp50rb with steer operate, don't activate the steer perform when accomplish the transverse resolution test. Zoom during the location wherever the targets Found if required. The diameter of the concentrate on point at a certain depth is equal to your transverse resolution on the depth. Web site seventy eight five.
Mindray respects your privacy. We use cookies for many different needs, for instance Web site operation, bettering your experience of our website, constructing integration with social networking and encouraging goal our promoting.
five.two.three Geometric positioning precision Longitudinal geometric positioning precision Take a look at Move: Do adjustments as the way in which in screening the utmost depth. History the space by 20mm Every segment within the longitudinal targets line using the measurement caliper; Pick the value with the greatest mistake (to 20mm), work out the precision using the formulation beneath The measurement caliper must be positioned for the upper fringe of the concentrate on, Observe:... Web site seventy nine Transverse geometric positioning accuracy Test Phase: Go over the scan surface of the phantom with h2o or few gel, gently contact the probe with the scan floor Modify the depth, making the transverse targets to be shown inside the graphic. Change the focus issue for being posited beside the transverse targets (the standard is not really obvious) Regulate parameters like obtain, TGC, earning Just about every transverse targets to become Plainly exhibited. Web page 80 5.5.2.four Blackout Location Check Stage: Protect the scan surface from the phantom with water or couple gel, Carefully Get in touch with the probe Along with the scan area Change the depth in a decrease price, and set the focus at the closest destination to the scan floor. Lessen the value of parameters like AP, Obtain right up until the track record noise just can be seen. Web site eighty one: Application Improve And Maintenance